3 Track Smart Chasing Controller

7 In stock

Light Controller

Product Code: 3 TRACK SMART CHASE

3 Track Smart Chaser Controller - 3 Channel Controller - Adjustable Speed Control - 10 amps per channel - Made in the USA - Smart Chasing Controllers feature internal dip switches that can be used to select a variety of chasing patterns.

Click here to learn how to create your own chasing light strings.

A few examples of what this controller can do:

2 Track Mode
3 Track Mode
3 Track, Back and Forth Mode

How to Set Your Chase Pattern

 To set your chase pattern, simply adjust the 4 sliders on the dip switch to an up-on-1 position or a down-off-0 position. To locate the dip switch, open the front cover of the box. The dip switch has 4 sliders located in the bottom right corner inside the box. Anytime that you change the sequence you MUST unplug the controller box and then plug it back in with the new sequence code for the change to take effect. The following is a description of the chase patterns available. Each chase pattern can be selected to run on a 2 track chase or a 3 track chase mode.

 

  1. Chase: Sequentially turns 1 track on and 2 tracks off from 1/10th to 2 seconds per step
  2. Wave: Turns lights on and off in a back and forth movement from 1/10th to 2 seconds per step
  3. Slow Chase: Chase pattern with speed range up to 6 seconds per step
  4. Slow Wave: Wave pattern with speed range up to 6 seconds per step
  5. Chase with Delay: Chase with a 3 times longer delay on step 1
  6. Wave with Delays: Wave with a 3 times longer delay on steps 1 and 3
  7. Negative Chase: Reverse of the chase pattern; sequentially turns 2 tracks on and 1 track off
  8. Build Up: Sequentially turns each track on, keeping it on until all tracks are on, then turns all tracks off together
  9. Speller: Build up that ends with all tracks flashing on and off together 3 times
  10. Multi-Sequence: A 20 second loop combining 7 different 3 second long chase patterns

 

Use the sequence list below to select the chase sequence you would like to run. When looking at the code setting, 1 represents up/on and 0 represents down/off. Be sure to select not only the pattern you want, but also the right pattern with the right number of tracks, 2 track mode or 3 track mode. Remember to un-plug and re-plug-in the controller box whenever you change the sequence. This Sequence Label is also printed on the top of the controller box.

Use dip switch on circuit board to select chase sequence. Move slides to match setting 1=ON/UP 0=OFF/DOWN
Remember: Unplug the controller before changing the settings.

Sequence # Setting Description Max Amps Per
1 1000 2 Track Chase 10
2 0000 3 Track Chase 10
3 1100 3 Track Wave 10
4 0001 2 Track Chase Slow 10
5 0010 3 Track Chase Slow 10
6 0011 3 Track Wave Slow 10
7 0100 2 Track Chase with Delay 10
8 0101 3 Track Chase with Delay 10
9 0110 3 Track Wave with Blank 10
10 0111 3 Track Chase with Blank 10
11 1001 3 Track Negative Chase 5
12 1010 2 Track Build Up 5
13 1011 3 Track Build Up 3
14 1101 3 Track Speller 3
15 1110 2 Track Multi Sequence 5
16 1111 3 Track Multi Sequence 3

 

Example: To select Sequence #1, the 2 Track Chase abbreviated 2TC with the setting 1000, use the dip switch inside your controller box and adjust the sliders going from left to right. Move the first slide into an upward position as indicated by the “1” and leave the rest of the slides (the last 3) in a downward position as indicated by the last three“0”s in the code setting. This will program the lights to move in a 2 track chase sequence.

 Maximum Load

 The maximum load for the 3TSC-10 is 10 amps. To see the maximum loads per receptacle, refer to the last column of the above Sequence Label, also located on top of the control box. The sequence label lists the “Max Amps per Receptacle” for each possible chase sequence that the controller can execute. The maximum amps per receptacle can vary depending on the sequence you choose because different sequences have different maximum numbers of receptacles that are turned on at any one time.

To calculate the number of bulbs that may be turned on per amp (amperage load) for any given receptacle, see the chart below

Amperage Load Chart (based on amps per receptacle)

Type of Light

# = 1 amp

# = 3 amp

# = 5 amp

# = 10 amp

C9 Incandescent 9 watt

14 bulbs

42 bulbs

70 bulbs

140 bulbs

C7 Incandescent 7 watt

18 bulbs

54 bulbs

90 bulbs

180 bulbs

C7 Incandescent 5 watt

21 bulbs

63 bulbs

105 bulbs

210 bulbs

Rope Light, Incandescent

21 feet

63 feet

105 feet

210 feet

C9 LED

50 bulbs

150 bulbs

250 bulbs

500 bulbs

C7 LED

70 bulbs

210 bulbs

350 bulbs

700 bulbs

Mini Lights Incandescent

300 bulbs

900 bulbs

1,500 bulbs

3,000 bulbs

Mini Lights LEDs

1,200 bulbs

3,600 bulbs

6,000 bulbs

12,000 bulbs

$215.00
+
-

To add this product to your wish list you must Sign In or Create an account

3 Track Smart Chaser Controller - 3 Channel Controller - Adjustable Speed Control - 10 amps per channel - Made in the USA - Smart Chasing Controllers feature internal dip switches that can be used to select a variety of chasing patterns.

Click here to learn how to create your own chasing light strings.

A few examples of what this controller can do:

2 Track Mode
3 Track Mode
3 Track, Back and Forth Mode

How to Set Your Chase Pattern

 To set your chase pattern, simply adjust the 4 sliders on the dip switch to an up-on-1 position or a down-off-0 position. To locate the dip switch, open the front cover of the box. The dip switch has 4 sliders located in the bottom right corner inside the box. Anytime that you change the sequence you MUST unplug the controller box and then plug it back in with the new sequence code for the change to take effect. The following is a description of the chase patterns available. Each chase pattern can be selected to run on a 2 track chase or a 3 track chase mode.

 

  1. Chase: Sequentially turns 1 track on and 2 tracks off from 1/10th to 2 seconds per step
  2. Wave: Turns lights on and off in a back and forth movement from 1/10th to 2 seconds per step
  3. Slow Chase: Chase pattern with speed range up to 6 seconds per step
  4. Slow Wave: Wave pattern with speed range up to 6 seconds per step
  5. Chase with Delay: Chase with a 3 times longer delay on step 1
  6. Wave with Delays: Wave with a 3 times longer delay on steps 1 and 3
  7. Negative Chase: Reverse of the chase pattern; sequentially turns 2 tracks on and 1 track off
  8. Build Up: Sequentially turns each track on, keeping it on until all tracks are on, then turns all tracks off together
  9. Speller: Build up that ends with all tracks flashing on and off together 3 times
  10. Multi-Sequence: A 20 second loop combining 7 different 3 second long chase patterns

 

Use the sequence list below to select the chase sequence you would like to run. When looking at the code setting, 1 represents up/on and 0 represents down/off. Be sure to select not only the pattern you want, but also the right pattern with the right number of tracks, 2 track mode or 3 track mode. Remember to un-plug and re-plug-in the controller box whenever you change the sequence. This Sequence Label is also printed on the top of the controller box.

Use dip switch on circuit board to select chase sequence. Move slides to match setting 1=ON/UP 0=OFF/DOWN
Remember: Unplug the controller before changing the settings.

Sequence # Setting Description Max Amps Per
1 1000 2 Track Chase 10
2 0000 3 Track Chase 10
3 1100 3 Track Wave 10
4 0001 2 Track Chase Slow 10
5 0010 3 Track Chase Slow 10
6 0011 3 Track Wave Slow 10
7 0100 2 Track Chase with Delay 10
8 0101 3 Track Chase with Delay 10
9 0110 3 Track Wave with Blank 10
10 0111 3 Track Chase with Blank 10
11 1001 3 Track Negative Chase 5
12 1010 2 Track Build Up 5
13 1011 3 Track Build Up 3
14 1101 3 Track Speller 3
15 1110 2 Track Multi Sequence 5
16 1111 3 Track Multi Sequence 3

 

Example: To select Sequence #1, the 2 Track Chase abbreviated 2TC with the setting 1000, use the dip switch inside your controller box and adjust the sliders going from left to right. Move the first slide into an upward position as indicated by the “1” and leave the rest of the slides (the last 3) in a downward position as indicated by the last three“0”s in the code setting. This will program the lights to move in a 2 track chase sequence.

 Maximum Load

 The maximum load for the 3TSC-10 is 10 amps. To see the maximum loads per receptacle, refer to the last column of the above Sequence Label, also located on top of the control box. The sequence label lists the “Max Amps per Receptacle” for each possible chase sequence that the controller can execute. The maximum amps per receptacle can vary depending on the sequence you choose because different sequences have different maximum numbers of receptacles that are turned on at any one time.

To calculate the number of bulbs that may be turned on per amp (amperage load) for any given receptacle, see the chart below

Amperage Load Chart (based on amps per receptacle)

Type of Light

# = 1 amp

# = 3 amp

# = 5 amp

# = 10 amp

C9 Incandescent 9 watt

14 bulbs

42 bulbs

70 bulbs

140 bulbs

C7 Incandescent 7 watt

18 bulbs

54 bulbs

90 bulbs

180 bulbs

C7 Incandescent 5 watt

21 bulbs

63 bulbs

105 bulbs

210 bulbs

Rope Light, Incandescent

21 feet

63 feet

105 feet

210 feet

C9 LED

50 bulbs

150 bulbs

250 bulbs

500 bulbs

C7 LED

70 bulbs

210 bulbs

350 bulbs

700 bulbs

Mini Lights Incandescent

300 bulbs

900 bulbs

1,500 bulbs

3,000 bulbs

Mini Lights LEDs

1,200 bulbs

3,600 bulbs

6,000 bulbs

12,000 bulbs

Limited Warranty Policy

All American Christmas Co. guarantees all of our products to be free of defects and workmanship for a period of 60 days from the date of shipment. All American Christmas Co. Assumes no responsibility in any event for payment or incidental consequential damages, of property. These products may present possible shock or fire hazard if not installed properly. This warranty is voided for products not installed according to current local codes and/or the National Electrical Code.

Return Policy

  • You must email for return authorization. Products shipped back without authorization will be held for pickup.
  • When returning products please include our All American Christmas Co. Item Return Form. You must return your items with this form. Click here to download the PDF form (Right Click, Save link as..., Save then open)
  • Products returned through no fault of All American Christmas Co., will be subject to a 15% restocking charge.
  • All returns must be shipped prepaid and goods must be in unused resalable condition in the original packaging.
  • When products that are returned through no fault of All American Christmas Co. you must assume responsibility for shipping the items back to us. We do not refund the shipping from the initial order.
  • When a package is returned shipped, we recommend, using a carrier that will track your package to make sure it safely gets back to us.
  • Absolutely NO RETURNS after 10 days. If damage occurs during shipping, you must immediately contact the freight carrier directly for compensation. Again, We cannot be held responsible for damage during shipment!
  • Keep all packing material and the box merchandise was shipped in for inspection; failure to do so will result in a rejected claim by the carrier. 
  • Any item that is returned that had the shipping cost included in the price will have the shipping cost deducted from the total for any calculations of the return.
  • Exceptions: If we ship a product by error this will be All American Christmas Co. responsibility to get you, the customer, the correct items.
  • NO RETURNS AFTER CHRISTMAS !!!

 


Warranty for Replacement Bulbs & Light Strings

  • All filament style bulbs are prone to burning out after a period of time.We will replace or credit your account for bulbs that burn out ON THEIR OWN if it happens within the Limited Warranty Policy shown above.
  • If a bulb burns out from too much power, improper wiring, mishandling, etc... we will NOT replace or credit them.
  • Our Choice to replace, repair, or credit items after they have been returned to us.Cancelled Order Clause
  • Any order that is cancelled after we process it is subject to either a 3% cancellation fee or a $10.00 minimum cancellation fee.
  • If a cancellation is requested and the order has already been processed, boxed and loaded for shipment there is no way this order can be retrieved. It will be treated as a return shipment subject to the standard conditions of the return policy.

Recently Viewed Products